Speed Monitor
SAFEONE DN3PD2

 

The SAFEONE DN3PD2 is a safety switching device for sensorless speed monitoring of three-phase and single-phase motors. Speed is detected by measuring the frequency of the motor's effective rotating field. The module is parameterized using the intuitive GO:BEYOND software and meets the certified performance level e or SIL 3.

Sensorless
Fits every Switch Cabinet
Configurable with Software

 

Request Product

Produktbild_SAFEONE_DN3PD2_mit_Logos (1)

 

Your advantages at a glance.

Kostenersparnis _ Kosteneffizienz

Cost effective

Lower costs, as no sensors need to be installed.

Unabhängig _ Freiheit

Independent

Can be used independently of providers and systems.

Kompakte Module _ Kompakte Bauweise

Space-saving

With a width of 22.5 mm, the speed monitor fits into any switch cabinet.

Zuverlässig _ Sicherheit

Reliable

Less prone to failure by eliminating the encoder.

Parametrierbar

Parameterizable

Our license-free software enables fast and straightforward configuration.

Plug&Play

Plug & Play

Quick and easy commissioning without sensor wiring.


 

Features

Relais_Diagnose Ausgang-1RelaisDiagnose Ausgang (3) sensorlos-1   Betriebsspannung-2 Breite 22,5mm-1Ple Merkmal ENSIL 3 Merkmal EN

Device variants

ID-No. Measuring voltage Frequency Inputs/outputs
34PD10 90V to 690V AC 0,5Hz to 1200Hz 2 Monitoring outputs
34PD11 24V to 120V AC 0,5Hz to 1200Hz 2 Monitoring outputs
34PD14 90V to 690V AC 100Hz to 1650Hz 2 Monitoring outputs
34PD20 90V to 690V AC 0,5Hz to 1200Hz 2 inputs for operating mode switchover or muting
34PD21 24V to 120V AC 0,5Hz to 1200Hz 2 inputs for operating mode switchover or muting
34PD24 90V to 690V AC 100Hz to 1650Hz 2 inputs for operating mode switchover or muting

Technical Data

Width 22,5 mm
Switching capacity up to 5 A
In- and Outputs 2 Relay Outputs (1 Safety Contact) + 2 Diagnostic Outputs or 2 inputs for operating mode switching
Connection Terminals Spring-loaded terminals, screw terminals
Certificates PLe (EN ISO 13849-1), SIL3 (IEC 61508), SIL CL3 (IEC 62061), UL-certified
Hardware-Parameterisation No
Software-Parameterisation Yes
Motion Monitoring no external sensor required
Hardware-Diagnosis/LED Yes
Safe Torque OFF (STO) Yes
Safe Operating Stop (SOS) Yes
Safe Speed Range (SSR) Yes
Safe Speed Monitor (SSM) Yes
Safe Limited Speed (SLS) Yes
Safe Maximum Speed (SMS) Yes
Safe Direction (SDR) No
Muting (bypass) Yes

 

General Data

Duty cycle 100%
Protection IP20
Protection class Installation site Switch Cabinet, min. IP54
Installation Site any
Clearance and creepage distances between circuits according to DIN EN 501788
Rated insulation voltage 400V AC
Rated surge voltage/ insulation Basic insulation 6kV: between all current paths and enclosures safe isolation, reinforced insulation 8kV: between U, V, W and USB interface between U,V,W and A1, A2, O1,O2 between U, V, W and 13/14, 23/24
Degree of contamination 2
Overvoltage category III
Housing material/ type Polyamide PA not reinforced/ ME/ Co. Phoenix Contact
Measurements B x H x T/ 22,5 x 114 x 111mm

 

Input Data

Operating Voltage 24V DC -15% / +10%
Current consumption at 24V DC typ. 80mA
Current consumption U, V, W 0,35mA at 690V AC
Input voltage at U, V, W 90 V to 690 V AC or 24 V to 120 V AC
Cut-off frequency at U, V, W 0,5 Hz to 1200 Hz or 100 Hz to 1650 Hz
Min. PWM 2kHz
Uncertainty of measurement 1%
Switch hysteresis 10%
Power consumption at A1/A2 typ. 1,9W
Status indicator 2x LED 2-coloured
Protection circuit Overvoltage and reverse polarity protection for operating voltage
Digital inputs 24V DC digital

 

Output Data

Relay Outputs
Contact design Bildschirmfoto 2024-09-23 um 14.08.57
Contact Material AgSnO2
Switch Voltage 24V DC / 230 V AC
Minimum switching current 10mA
Mechanical Lifetime 10^7 Switch Cycles
Response time Number of measuring cycles x (period duration (reciprocal of frequency) + max. 2ms evaluation time) + max. 10ms relay response time
Output fuse 6A gL/gG
Switching capacity according to IEC 60947-5-1 AC15: 5A/230V, DC13: 4A/24V

 

Message Outputs

Number of Outputs 2 (non-safety-related, digital outputs O1, O2)
Power ≤ 100mA, short-circuit and overload protected
Voltage UB - 1V

Block Diagram

SAFEONE_DN3PD2_Blockschaltbild

Sample Application

SAFEONE_DN3PD2_Applikationsbeispiel_neu

Stop Category according to IEC 60204-1 0
Category according to DIN ISO 13849 4
Performance Level e
Demand rate < 12 Months
Proof-Test-Interval 20 Years

 

Safety Features

Safe Speed Range (SSR) Yes
Safe Limited Speed (SLS) Yes
Safe Maximum Speed (SMS) Yes
Safe Speed Monitor Yes
Safe Maximum Speed (SMS) Yes
Safe Direction (SDR) No

Compatibility

  • Three-phase motor with frequency converter
  • Single-phase AC motors
  • Motors with star-delta connection
  • Servo Motors
  • Centrifuges

 


 

Request SAFEONE DN3PD2

Whether retrofitting or planning state-of-the-art machines up to performance level e.
Safe speed monitoring does not have to be complicated.