Phase monitor
SAFEONE DN3PW
The phase monitors reliably monitor the supply voltage in three-phase networks. The SAFEONE DN3PW2 is designed for safety-related applications, while the SAFEONE DN3PW1 is suitable for non-safety-related applications.
Your advantages at a glance.
Unique on the market
The SAFEONE DN3PW2 is the first series-ready, separate safety switching device for safe phase monitoring.
Easy diagnosis and compact protection
The device enables easy diagnostics via LED indicators and offers compact protection against the consequences of power supply disturbances.
Detection of phase fluctuations
The SAFEONE DN3PW2 detects the most important phase faults such as phase failure, asymmetry, and under- and overvoltage.
Adjustable response time
The response time of the phase monitor can be set individually.
Adaptable to any grid situation
The reference voltage can be flexibly adapted to any grid situation: teach for grids with strong voltage fluctuations or 400V fixed for stable grids.
.png?width=160&height=284&name=PW2_Merkmal%20(10).png)
![]()
.png?width=160&height=284&name=PW2_Merkmal%20(7).png)

![]()
![]()
Measuring inputs
| Measuring inputs | L1, L2, L3 |
| Maximaum rated voltage | 277/480V AC |
| Minimum rated voltage (teaching) | 80V/140V AC |
| Input frequency | 50 bis 60 Hz |
| Maximum current consumption | 0,55 mA per input |
| Maximum line length | 30m |
General data
| Protection rating (housing and terminals) | IP20 |
| Protection rating (installation location) | min. IP 54 |
| Clearances and creepage distances between circuits | As per DIN EN 50178 |
| Rated insulation voltage (13/14, 23/24) | 480V AC |
| Rated impulse voltage / insulation | 6 kV |
| Degree of contamination | 2 |
| Overvoltage category | III |
| Housing material | Polyamid PA, not reinforced |
Ambient conditions
| Operating temperature | -10 °C to + 55 °C |
| Storage temperature | -40 °C to + 85 °C |
| Altitude of the area of use | < 2000 m above sea level |
| Shock | 10g |
Further technical data can be found in the manual, which you can download under Downloads.
Block diagram

Application example

S1= Switch for deactivating monitoring
Safety-related parameters according to DIN EN ISO 13849-1:2023-12
| Category | 3 |
| Performance Level | d |
| MTTFd [a] DC13, 1A, 10 switching operations/h |
100 |
Safety parameters according to EN ISO 61508-High Demand
| HFT | 1 |
| SIL | 2 |
| PFHd [h] DC13, 1A, 10 switching operations/h |
4,29 x 10⁻⁸ |
| Demand rate | < 12 Monate |
| Operating life | 240 months |
Application
In production lines with electric overhead conveyors (EOC), the safe phase monitor specifically monitors conductor rails. If a rail is switched off, the device detects this and thus enables the controlled shutdown of a system.
For drives that can feed energy back into the grid (e.g., during braking), the phase monitor ensures that energy is only fed in when the supply voltage is correct, complete, and stable.
Phase Monitor SAFEONE DN3PW1
The SAFEONE DN3PW1 monitors the three phases of the supply voltage of electrical systems or system components for phase relationship and voltage values. In the event of a fault, it reacts within at least ten milliseconds. The switching device is not intended for safety-related applications.
Your advantages at a glance.
Easy diagnosis and compact protection
The device enables easy diagnostics via LED indicators and offers compact protection against the consequences of power supply disturbances.
Detection of phase fluctuations
The SAFEONE DN3PW1 detects the most important phase faults such as phase failure, phase relationship, and under- and overvoltage.
Fast response time
The phase monitor reacts at lightning speed within at least 10 ms in the event of a fault.
.png?width=160&height=284&name=PW2_Merkmal%20(3).png)


Measuring inputs
| Measuring inputs | L1, L2, L3 |
| Maximum voltage | 540V AC |
| Nominal voltage | 400V AC |
| Measurement voltage tolerance | -15%/+10% |
| Current consumption | 0,55mA per input |
General data
| Type of protection (housing and terminals) | IP20 |
| Type of protection (place of installation) | min. IP 54 |
| Clearance and creepage distances between circuits | In accordance with DIN EN 50178 |
| Rated insulation voltage | 50V AC |
| Rated surge voltage/insulation | 0,8 kV |
| Degree of contamination | 2 |
| Overvoltage category | III |
| Housing material | Polyamide (PA), not reinforced |
Environmental conditions
| Operating temperature | -10 °C to + 55 °C |
| Storage temperature | -40 °C to + 85 °C |
| Attitude of place of use | < 2000 m above sea level |
Further technical data can be found in the manual, which you can download under Downloads.
Block diagram

Application example

S1= Switch for deactivating monitoring
Contact service life
Electrical life of the output contacts according to DIN EN 60947-5-1/ Appendix C.3

Application
The phase monitor is used to monitor the supply voltage of machines operated under unstable grid conditions. If a grid failure is imminent, the device detects it immediately and enables movements to stop or reverse in time to prevent damage to workpieces, tools, or system components.
For drives that can feed energy back into the grid (e.g., during braking), the phase monitor ensures that energy is only fed in when the supply voltage is correct, complete, and stable.